* Three different validations are conducted in
the welding database. The objective is to ensure the comprehensive integrity of
all joint criteria. *
* *
*1. Click on the button “Run
validation” that is only in the general tab of the header of the welding db.*
1.1 *Invalid Records.*
Invalid records are those
containing at least one welding criteria that does not comply with the
specified rules for them.
All records that have at
least one should
be listed in the Invalid Records table.
1.2* Duplicate Records*
- We categorize criteria into two types: single value-based and
range-based.
Single value-based criteria apply to the properties of Special
Joint Type, Surface Finish, Part Interface Orientation, Aperture Angle, Floor
Angle, Pass Number and Total Pass Number.
The second type
Instructions
*1. For the cells with a dropdown: multiple possible values columns, meaning usually the ones that contain text in the cells and not numbers.*
1.1 Right click on any cell in any columns that are not in the columns "Last Modified" or in "Debug".
1.2 To modify one cell, you only click right on one cell. For example, in the picture below, you can see I clicked right on a cell in Surface Finish. To modify one cell, you only click right on one cell. A menu bar will appear with four options.
1.3 To modify multiple cells
1.3.1 Select Rows*:
Press the Shift* key on your keyboard. Simultaneously, click on the first row* you want to edit. Then, click on the last row* in the range you wish to modify. 1.3.2 Batch Edit*:
As shown in the picture below, you’ll notice that multiple
The air conditioning unit (Rittal SK3305.510) included with the LayoutMaster has a few settings that needs to be changed from the factory settings.
1- Make sure that the A/C has power. The display on the A/C should show the actual internal temperature
2- Press and hold the SET button for 5 seconds until "ST" appears on the display. Release the SET button once "ST" is displayed
3- From this menu, you can cycle up or down using the UP/DOWN ( °C/°F) buttons. This will let you cycle trough all the settings that can be changed. Here is a list of settings that can be changed:
St (Set Temperature)*
Fi (Filter Monitoring)
Ad (Master-slave)
CF ( Celsius/Faranheit)
H1 (Hysteresis)
*H2 (Differential Error)*
ECO (Eco-mode)*
PSO (Password)
We will only change the settings in Bold (St, H2 & ECO)*
4- Us
*
AGT Robotics
recommande que l'entretien du système soit effectuée « par fréquence ». Le fichier Excel du Tableau de maintenance
globale contient 3 onglets :
Articles
regroupés par fréquence Articles
regroupés par composante Liste complète de
tous les éléments de maintenance
Chaque élément
dispose d'un lien vers un document ou une procédure de référence pour expliquer
comment effectuer l'entretien. Les
informations détaillées sur chaque élément sont en cours de révision et le
contenu est mis à jour régulièrement.
Remarque
importante : en fonction de l'utilisation du système, la fréquence de
maintenance peut être ajustée